Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Voltage - Rated | Size / Dimension | Width | Air Flow | Static Pressure | Bearing Type | Fan Type | Features | Noise | Power (Watts) | RPM | Termination | Ingress Protection | Operating Temperature | Approval Agency | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
9GL1224G101FAN AXIAL 119X38MM 24VDC WIRE Sanyo Denki America Inc. |
195 |
|
![]() Datasheet |
San Ace 120L | Box | Active | 24VDC | Square - 119mm L x 119mm H | 38.00mm | 137.0 CFM (3.84m³/min) | 0.542 in H2O (135.0 Pa) | Ball | Tubeaxial | Speed Sensor (Tach) | 49.0dB(A) | 12 W | 3600 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.816 lb (370.13 g) |
![]() |
9GA0924P1H01FAN AXIAL 92X38MM 24VDC WIRE Sanyo Denki America Inc. |
378 |
|
![]() Datasheet |
San Ace 92 | Box | Active | 24VDC | Square - 92mm L x 92mm H | 38.00mm | 141.0 CFM (3.95m³/min) | 2.010 in H2O (500.7 Pa) | Ball | Tubeaxial | PWM Control, Speed Sensor (Tach) | 63.0dB(A) | 26.4 W | 9700 RPM | 4 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CSA, TUV, UL | 0.529 lb (240.00 g) |
|
9GA0912P1H03FAN AXIAL 92X38MM 12VDC WIRE Sanyo Denki America Inc. |
129 |
|
![]() Datasheet |
San Ace 92 | Box | Active | 12VDC | Square - 92mm L x 92mm H | 38.00mm | 141.2 CFM (3.95m³/min) | 2.010 in H2O (500.7 Pa) | Ball | Tubeaxial | PWM Control, Speed Sensor (Tach) | 63.0dB(A) | 25.2 W | 9700 RPM | 4 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.529 lb (239.95 g) |
![]() |
9BMB12P2K01FAN BLOWER 97.1X33MM 12VDC WIRE Sanyo Denki America Inc. |
9,602 |
|
![]() Datasheet |
San Ace B97 | Box | Active | 12VDC | Rectangular/Rounded - 97.1mm L x 95mm H | 33.00mm | 56.8 CFM (1.59m³/min) | 5.140 in H2O (1280.0 Pa) | Ball | Blower | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 66.0dB(A) | 40.8 W | 6850 RPM | 4 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV | 0.419 lb (190.06 g) |
|
9GV0824P1G03FAN AXIAL 80X38MM 24VDC WIRE Sanyo Denki America Inc. |
365 |
|
![]() Datasheet |
San Ace 80 | Box | Active | 24VDC | Square - 80mm L x 80mm H | 38.00mm | 138.0 CFM (3.86m³/min) | 1.970 in H2O (490.7 Pa) | Ball | Tubeaxial | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 65.0dB(A) | 38.4 W | 10200 RPM | 4 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.485 lb (220.00 g) |
![]() |
9CRA0612P6K001FAN AXIAL DUAL 60X56MM 12VDC Sanyo Denki America Inc. |
3,120 |
|
![]() Datasheet |
San Ace 60 | Box | Active | 12VDC | Square - 60mm L x 60mm H | 56.00mm | 80.2 CFM (2.25m³/min) | 4.540 in H2O (1130.8 Pa) | Ball | Tubeaxial (Dual) | Counter-Rotating, Locked Rotor Protection, Speed Sensor (Tach) | 73.0dB(A) | 37.2 W | 18300 Front, 15800 Rear | 3 Wire Leads per Fan | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV | 0.441 lb (200.00 g) |
|
9GV0912P1G03FAN AXIAL 92X38MM 12VDC WIRE Sanyo Denki America Inc. |
444 |
|
![]() Datasheet |
San Ace 92 | Box | Active | 12VDC | Square - 92mm L x 92mm H | 38.00mm | 189.0 CFM (5.29m³/min) | 1.730 in H2O (430.9 Pa) | Ball | Tubeaxial | PWM Control, Speed Sensor (Tach) | 68.0dB(A) | 49.2 W | 9000 RPM | 4 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.553 lb (250.84 g) |
![]() |
9BFB12P2H003FAN BLOWER 120X32MM 12VDC WIRE Sanyo Denki America Inc. |
1,067 |
|
![]() Datasheet |
San Ace B120 | Box | Active | 12VDC | Square/Rounded - 120mm L x 120mm H | 32.00mm | 56.5 CFM (1.58m³/min) | 5.020 in H2O (1250.0 Pa) | Ball | Blower | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 62.0dB(A) | 27.6 W | 3750 RPM | 4 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV | 0.75 lb (340.19 g) |
|
9RA1248P1K001120X38MM 48VDC TACH/PWM Sanyo Denki America Inc. |
210 |
|
![]() Datasheet |
San Ace 120 | Box | Active | 48VDC | Square - 120mm L x 120mm H | 38.00mm | 158.0 CFM (4.42m³/min) | 0.683 in H2O (170.0 Pa) | Ball | Tubeaxial | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 50.0dB(A) | 12 W | 4700 RPM | 4 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV | - |
![]() |
9HV0924P4G001FAN AXIAL 92X25.2MM 24VDC WIRE Sanyo Denki America Inc. |
2,146 |
|
![]() Datasheet |
San Ace 92 | Bulk | Active | 24VDC | Square - 92mm L x 92mm H | 25.20mm | 118.0 CFM (3.30m³/min) | 1.120 in H2O (279.0 Pa) | Ball | Tubeaxial | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 56.0dB(A) | 14.64 W | 7350 RPM | 4 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV | - |