Turret Connectors

制造商 Series Packaging Product Status Terminal Type Number of Turrets Length - Above Board Length - Below Flange Length - Overall Mounting Type Termination Flange Diameter Diameter - Turret Head Staking Side OD Staking Side ID Mounting Hole Diameter Board Thickness Contact Material Contact Finish Contact Finish Thickness Insulation







































































































































































































































































































































































































































































































































































































































































































































































































































































































全部重置
应用所有
结果:
Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Terminal Type Number of Turrets Length - Above Board Length - Below Flange Length - Overall Mounting Type Termination Flange Diameter Diameter - Turret Head Staking Side OD Staking Side ID Mounting Hole Diameter Board Thickness Contact Material Contact Finish Contact Finish Thickness Insulation
H2074Z01

H2074Z01

TERM TURRET SLOTTED L=8.74MM TIN

Harwin Inc.

3,819
RFQ
H2074Z01

Datasheet

- Bulk Active Single End, Fork Triple 0.344" (8.74mm) 0.171" (4.34mm) 0.515" (13.08mm) Through Hole Swage 0.250" (6.35mm) 0.180" (4.57mm) 0.152" ~ 0.154" (3.86mm ~ 3.92mm) 0.109" ~ 0.112" (2.77mm ~ 2.85mm) 0.155" ~ 0.159" (3.94mm ~ 4.04mm) 0.126" (3.20mm) Brass Alloy Tin - Non-Insulated
2717-4-00-01-00-00-07-0

2717-4-00-01-00-00-07-0

TERM TURRET DOUBLE L=7.14MM

Mill-Max Manufacturing Corp.

1,656
RFQ
2717-4-00-01-00-00-07-0

Datasheet

2717 Bulk Active Double End Single, Double 0.281" (7.14mm) 0.238" (6.05mm) 0.519" (13.18mm) Through Hole Swage 0.156" (3.96mm) 0.070" (1.78mm), 0.109" (2.77mm) - - 0.094" (2.39mm) 0.125" (3.18mm) Brass Alloy Tin-Lead 200.0µin (5.08µm) Non-Insulated
2717-4-00-50-00-00-07-0

2717-4-00-50-00-00-07-0

TERM TURRET DOUBLE L=7.14MM

Mill-Max Manufacturing Corp.

3,823
RFQ
2717-4-00-50-00-00-07-0

Datasheet

2717 Bulk Active Double End Single, Double 0.281" (7.14mm) 0.238" (6.05mm) 0.519" (13.18mm) Through Hole Swage 0.156" (3.96mm) 0.070" (1.78mm), 0.109" (2.77mm) - - 0.094" (2.39mm) 0.125" (3.18mm) Brass Alloy Tin-Lead 300.0µin (7.62µm) Non-Insulated
2717-4-00-80-00-00-07-0

2717-4-00-80-00-00-07-0

TERM TURRET DBL

Mill-Max Manufacturing Corp.

1,150
RFQ
2717-4-00-80-00-00-07-0

Datasheet

2717 Bulk Active Double End Single, Double 0.281" (7.14mm) 0.238" (6.05mm) 0.519" (13.18mm) Through Hole Swage 0.156" (3.96mm) 0.070" (1.78mm), 0.109" (2.77mm) - - 0.094" (2.39mm) 0.125" (3.18mm) Brass Alloy Tin 200.0µin (5.08µm) Non-Insulated
2802-1-00-01-00-00-07-0

2802-1-00-01-00-00-07-0

TERM TURRET SINGLE L=7.92MM

Mill-Max Manufacturing Corp.

1,282
RFQ
2802-1-00-01-00-00-07-0

Datasheet

2802 Bulk Active Single End Double 0.312" (7.92mm) 0.078" (1.98mm) 0.390" (9.91mm) Through Hole Swage 0.187" (4.75mm) 0.150" (3.81mm) 0.112" (2.84mm) 0.078" (1.98mm) 0.118" (3.00mm) 0.031" (0.79mm) Brass Alloy Tin-Lead 200.0µin (5.08µm) Non-Insulated
2802-1-00-50-00-00-07-0

2802-1-00-50-00-00-07-0

TERM TURRET SINGLE L=7.92MM

Mill-Max Manufacturing Corp.

1,958
RFQ
2802-1-00-50-00-00-07-0

Datasheet

2802 Bulk Active Single End Double 0.312" (7.92mm) 0.078" (1.98mm) 0.390" (9.91mm) Through Hole Swage 0.187" (4.75mm) 0.150" (3.81mm) 0.112" (2.84mm) 0.078" (1.98mm) 0.118" (3.00mm) 0.031" (0.79mm) Brass Alloy Tin-Lead 300.0µin (7.62µm) Non-Insulated
2802-1-00-80-00-00-07-0

2802-1-00-80-00-00-07-0

TERM TURRET SNG

Mill-Max Manufacturing Corp.

4,947
RFQ
2802-1-00-80-00-00-07-0

Datasheet

2802 Bulk Active Single End Double 0.312" (7.92mm) 0.078" (1.98mm) 0.390" (9.91mm) Through Hole Swage 0.187" (4.75mm) 0.150" (3.81mm) 0.112" (2.84mm) 0.078" (1.98mm) 0.118" (3.00mm) 0.031" (0.79mm) Brass Alloy Tin 200.0µin (5.08µm) Non-Insulated
2702-1-00-44-00-00-07-0

2702-1-00-44-00-00-07-0

TERM TURRET SINGLE L=7.14MM

Mill-Max Manufacturing Corp.

1,859
RFQ
2702-1-00-44-00-00-07-0

Datasheet

2702 Bulk Active Single End Single 0.281" (7.14mm) 0.075" (1.91mm) 0.356" (9.04mm) Through Hole Swage 0.156" (3.96mm) 0.109" (2.77mm) 0.090" (2.29mm) 0.064" (1.63mm) 0.094" (2.39mm) 0.031" (0.79mm) Brass Alloy Silver 300.0µin (7.62µm) Non-Insulated
2704-2-00-44-00-00-07-0

2704-2-00-44-00-00-07-0

TERM TURRET SINGLE L=8.33MM

Mill-Max Manufacturing Corp.

1,454
RFQ
2704-2-00-44-00-00-07-0

Datasheet

2704 Bulk Active Single End Double 0.328" (8.33mm) 0.105" (2.67mm) 0.433" (11.00mm) Through Hole Swage 0.156" (3.96mm) 0.109" (2.77mm) 0.078" (1.98mm) 0.055" (1.40mm) 0.082" (2.08mm) 0.062" (1.57mm) Brass Alloy Silver 300.0µin (7.62µm) Non-Insulated
2802-2-00-01-00-00-07-0

2802-2-00-01-00-00-07-0

TERM TURRET SINGLE L=7.92MM

Mill-Max Manufacturing Corp.

4,694
RFQ
2802-2-00-01-00-00-07-0

Datasheet

2802 Bulk Active Single End Double 0.312" (7.92mm) 0.109" (2.77mm) 0.421" (10.69mm) Through Hole Swage 0.187" (4.75mm) 0.150" (3.81mm) 0.112" (2.84mm) 0.078" (1.98mm) 0.118" (3.00mm) 0.062" (1.57mm) Brass Alloy Tin-Lead 200.0µin (5.08µm) Non-Insulated
2802-2-00-50-00-00-07-0

2802-2-00-50-00-00-07-0

TERM TURRET SINGLE L=7.92MM

Mill-Max Manufacturing Corp.

2,109
RFQ
2802-2-00-50-00-00-07-0

Datasheet

2802 Bulk Active Single End Double 0.312" (7.92mm) 0.109" (2.77mm) 0.421" (10.69mm) Through Hole Swage 0.187" (4.75mm) 0.150" (3.81mm) 0.112" (2.84mm) 0.078" (1.98mm) 0.118" (3.00mm) 0.062" (1.57mm) Brass Alloy Tin-Lead 300.0µin (7.62µm) Non-Insulated
2802-2-00-80-00-00-07-0

2802-2-00-80-00-00-07-0

TERM TURRET SNG

Mill-Max Manufacturing Corp.

3,463
RFQ
2802-2-00-80-00-00-07-0

Datasheet

2802 Bulk Active Single End Double 0.312" (7.92mm) 0.109" (2.77mm) 0.421" (10.69mm) Through Hole Swage 0.187" (4.75mm) 0.150" (3.81mm) 0.112" (2.84mm) 0.078" (1.98mm) 0.118" (3.00mm) 0.062" (1.57mm) Brass Alloy Tin 200.0µin (5.08µm) Non-Insulated
2704-3-00-44-00-00-07-0

2704-3-00-44-00-00-07-0

TERM TURRET SINGLE L=8.33MM

Mill-Max Manufacturing Corp.

1,991
RFQ
2704-3-00-44-00-00-07-0

Datasheet

2704 Bulk Active Single End Double 0.328" (8.33mm) 0.135" (3.43mm) 0.463" (11.76mm) Through Hole Swage 0.156" (3.96mm) 0.109" (2.77mm) 0.078" (1.98mm) 0.055" (1.40mm) 0.082" (2.08mm) 0.094" (2.39mm) Brass Alloy Silver 300.0µin (7.62µm) Non-Insulated
2713-1-00-01-00-00-07-0

2713-1-00-01-00-00-07-0

TERM TURRET DOUBLE L=7.14MM

Mill-Max Manufacturing Corp.

2,564
RFQ
2713-1-00-01-00-00-07-0

Datasheet

2713 Bulk Active Double End Double 0.281" (7.14mm) 0.226" (5.74mm) 0.507" (12.88mm) Through Hole Swage 0.156" (3.96mm) 0.070" (1.78mm), 0.109" (2.77mm) - - 0.094" (2.39mm) 0.031" (0.79mm) Brass Alloy Tin-Lead 200.0µin (5.08µm) Non-Insulated
2713-1-00-50-00-00-07-0

2713-1-00-50-00-00-07-0

TERM TURRET DOUBLE L=7.14MM

Mill-Max Manufacturing Corp.

1,847
RFQ
2713-1-00-50-00-00-07-0

Datasheet

2713 Bulk Active Double End Double 0.281" (7.14mm) 0.226" (5.74mm) 0.507" (12.88mm) Through Hole Swage 0.156" (3.96mm) 0.070" (1.78mm), 0.109" (2.77mm) - - 0.094" (2.39mm) 0.031" (0.79mm) Brass Alloy Tin-Lead 300.0µin (7.62µm) Non-Insulated
2713-1-00-80-00-00-07-0

2713-1-00-80-00-00-07-0

TERM TURRET DBL

Mill-Max Manufacturing Corp.

4,545
RFQ
2713-1-00-80-00-00-07-0

Datasheet

2713 Bulk Active Double End Double 0.281" (7.14mm) 0.226" (5.74mm) 0.507" (12.88mm) Through Hole Swage 0.156" (3.96mm) 0.070" (1.78mm), 0.109" (2.77mm) - - 0.094" (2.39mm) 0.031" (0.79mm) Brass Alloy Tin 200.0µin (5.08µm) Non-Insulated
2713-2-00-44-00-00-07-0

2713-2-00-44-00-00-07-0

TERM TURRET DOUBLE L=7.14MM

Mill-Max Manufacturing Corp.

4,186
RFQ
2713-2-00-44-00-00-07-0

Datasheet

2713 Bulk Active Double End Double 0.281" (7.14mm) 0.258" (6.55mm) 0.539" (13.69mm) Through Hole Swage 0.156" (3.96mm) 0.070" (1.78mm), 0.109" (2.77mm) - - 0.094" (2.39mm) 0.062" (1.57mm) Brass Alloy Silver 300.0µin (7.62µm) Non-Insulated
2802-3-00-01-00-00-07-0

2802-3-00-01-00-00-07-0

TERM TURRET SINGLE L=7.92MM

Mill-Max Manufacturing Corp.

2,294
RFQ
2802-3-00-01-00-00-07-0

Datasheet

2802 Bulk Active Single End Double 0.312" (7.92mm) 0.140" (3.56mm) 0.452" (11.48mm) Through Hole Swage 0.187" (4.75mm) 0.150" (3.81mm) 0.112" (2.84mm) 0.078" (1.98mm) 0.118" (3.00mm) 0.094" (2.39mm) Brass Alloy Tin-Lead 200.0µin (5.08µm) Non-Insulated
2802-3-00-50-00-00-07-0

2802-3-00-50-00-00-07-0

TERM TURRET SINGLE L=7.92MM

Mill-Max Manufacturing Corp.

1,911
RFQ
2802-3-00-50-00-00-07-0

Datasheet

2802 Bulk Active Single End Double 0.312" (7.92mm) 0.140" (3.56mm) 0.452" (11.48mm) Through Hole Swage 0.187" (4.75mm) 0.150" (3.81mm) 0.112" (2.84mm) 0.078" (1.98mm) 0.118" (3.00mm) 0.094" (2.39mm) Brass Alloy Tin-Lead 300.0µin (7.62µm) Non-Insulated
2802-3-00-80-00-00-07-0

2802-3-00-80-00-00-07-0

TERM TURRET SNG

Mill-Max Manufacturing Corp.

1,675
RFQ
2802-3-00-80-00-00-07-0

Datasheet

2802 Bulk Active Single End Double 0.312" (7.92mm) 0.140" (3.56mm) 0.452" (11.48mm) Through Hole Swage 0.187" (4.75mm) 0.150" (3.81mm) 0.112" (2.84mm) 0.078" (1.98mm) 0.118" (3.00mm) 0.094" (2.39mm) Brass Alloy Tin 200.0µin (5.08µm) Non-Insulated
Total 1119 Record«Prev1... 4344454647484950...56Next»
Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER