| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Input Type | Input Range (Current, Voltage) | Input Range (Additional) | Output Type | Output Range | Isolation | Features | Voltage - Supply | Mounting Type | Termination Style | Operating Temperature | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|   | RN42-AA1AUACTIVE BARRIER SCREW BOTTOM Endress+Hauser | 3,591 |  |   Datasheet | RN42 | Box | Active | Signal Conditioner | Current | 0 ~ 20mA (Configurable) | - | Current | 0 ~ 20mA (Configurable) | 3000VAC (Test) | - | 24 ~ 230VAC/VDC | DIN Rail | Screw Terminal | -40°C ~ 60°C | 
|   | RN22-8L1BACTIVE BARRIER ATEX 1-CHANNEL Endress+Hauser | 2,418 |  |   Datasheet | RN22 | Box | Active | Signal Conditioner | Current | 0 ~ 20mA (Configurable) | - | Current | 0 ~ 20mA (Configurable) | 3000VAC (Test) | - | 24V | DIN Rail | Screw Terminal | -40°C ~ 60°C | 
|   | RN22-CB1B+LTACTIVE BARRIER CSA 1-CHANNEL Endress+Hauser | 1,350 |  |   Datasheet | RN22 | Box | Active | Signal Conditioner | Current | 0 ~ 20mA (Configurable) | - | Current | 0 ~ 20mA (Configurable) | 3000VAC (Test) | - | 24V | DIN Rail | Screw Terminal | -40°C ~ 60°C | 
|   | RN22-AA2A+LTACTIVE BARRIER 2-CHANNEL SCREW Endress+Hauser | 3,161 |  |   Datasheet | RN22 | Box | Active | Signal Conditioner | Current | 0 ~ 20mA (Configurable) | - | Current | 0 ~ 20mA (Configurable) | 3000VAC (Test) | - | 24V | DIN Rail | Screw Terminal | -40°C ~ 60°C | 
|   | RLN22-AA1AISOLATION AMPLIFIER, 1-CHANNEL Endress+Hauser | 2,266 |  |   Datasheet | RLN22 | Box | Active | Isolation Amplifier | - | - | - | - | - | 375V | Alarm Relay | 24V | DIN Rail | Screw Terminal | -40°C ~ 60°C | 
|   | RLN22-8M2A+LAISOLATION AMPLIFIER, 2-CHANNEL Endress+Hauser | 4,850 |  |   Datasheet | RLN22 | Box | Active | Isolation Amplifier | - | - | - | - | - | 375V | Alarm Relay | 24V | DIN Rail | Screw Terminal | -40°C ~ 60°C | 
|   | RN42-AA1AOACTIVE BARRIER SCREW TOP Endress+Hauser | 1,943 |  |   Datasheet | RN42 | Box | Active | Signal Conditioner | Current | 0 ~ 20mA (Configurable) | - | Current | 0 ~ 20mA (Configurable) | 3000VAC (Test) | - | 24 ~ 230VAC/VDC | DIN Rail | Screw Terminal | -40°C ~ 60°C | 
|   | RN42-AA1BUACTIVE BARRIER PUSH-IN BOTTOM Endress+Hauser | 3,689 |  |   Datasheet | RN42 | Box | Active | Signal Conditioner | Current | 0 ~ 20mA (Configurable) | - | Current | 0 ~ 20mA (Configurable) | 3000VAC (Test) | - | 24 ~ 230VAC/VDC | DIN Rail | Screw Terminal | -40°C ~ 60°C | 
|   | RLN42-8M2B+LAISOLATION AMPLIFIER, 2-CHANNEL Endress+Hauser | 4,450 |  |   Datasheet | RLN42 | Box | Active | Isolation Amplifier | - | - | - | - | - | 375V | - | 19.2 ~ 253VAC/VDC | DIN Rail | - | -40°C ~ 60°C | 
|   | RN42-CB1AOACTIVE BARRIER SCREW TOP CSA Endress+Hauser | 3,613 |  |   Datasheet | RN42 | Box | Active | Signal Conditioner | Current | 0 ~ 20mA (Configurable) | - | Current | 0 ~ 20mA (Configurable) | 3000VAC (Test) | - | 24 ~ 230VAC/VDC | DIN Rail | Screw Terminal | -40°C ~ 60°C |