| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Function | Voltage - Supply | Trip Range | Delay Time | Mounting Type | Termination Style | Features | Operating Temperature | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|   | EL731-21-00AC/DC EARTH-LKGE RELAY | 1,544 |  |   Datasheet | EL731 | Bulk | Active | Ground Fault, Overtemperature | 24VDC | 0.03 ~ 5A | 0.05 ~ 2s | Panel Mount | Screw Terminal | CT Loop Monitoring, Harmonic Filtering | -40°C ~ 60°C | 
|   | EL731-22-00AC/DC EARTH-LKGE RELAY | 1,449 |  |   Datasheet | EL731 | Bulk | Active | Ground Fault, Overtemperature | 24VDC | 0.03 ~ 5A | 0.05 ~ 2s | Panel Mount | Screw Terminal | CT Loop Monitoring, Harmonic Filtering | -40°C ~ 60°C | 
|   | EL731-23-00AC/DC EARTH-LKGE RELAY | 1,610 |  |   Datasheet | EL731 | Bulk | Active | Ground Fault, Overtemperature | 24VDC | 0.03 ~ 5A | 0.05 ~ 2s | Panel Mount | Screw Terminal | CT Loop Monitoring, Harmonic Filtering | -40°C ~ 60°C | 
|   | EL731-24-00AC/DC EARTH-LKGE RELAY | 2,706 |  |   Datasheet | EL731 | Bulk | Active | Ground Fault, Overtemperature | 24VDC | 0.03 ~ 5A | 0.05 ~ 2s | Panel Mount | Screw Terminal | CT Loop Monitoring, Harmonic Filtering | -40°C ~ 60°C | 
|   | EL731-21-10AC/DC EARTH-LKGE RELAY | 3,702 |  |   Datasheet | EL731 | Bulk | Active | Ground Fault, Overtemperature | 24VDC | 0.03 ~ 5A | 0.05 ~ 2s | Panel Mount | Spring Terminal | CT Loop Monitoring, Harmonic Filtering | - | 
|   | EL731-22-10AC/DC EARTH-LKGE RELAY | 1,390 |  |   Datasheet | EL731 | Bulk | Active | Ground Fault, Overtemperature | 24VDC | 0.03 ~ 5A | 0.05 ~ 2s | Panel Mount | Spring Terminal | CT Loop Monitoring, Harmonic Filtering | - | 
|   | EL731-23-10AC/DC EARTH-LKGE RELAY | 2,845 |  |   Datasheet | EL731 | Bulk | Active | Ground Fault, Overtemperature | 24VDC | 0.03 ~ 5A | 0.05 ~ 2s | Panel Mount | Spring Terminal | CT Loop Monitoring, Harmonic Filtering | - | 
|   | EL731-24-10AC/DC EARTH-LKGE RELAY | 1,057 |  |   Datasheet | EL731 | Bulk | Active | Ground Fault, Overtemperature | 24VDC | 0.03 ~ 5A | 0.05 ~ 2s | Panel Mount | Spring Terminal | CT Loop Monitoring, Harmonic Filtering | - | 
|   | 2-1618100-8D101-5X=WILMAR CLOSE DIFFERENT | 3,749 |  |   Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | 
|   | 6-1618082-4401-43SX=RELAY, UNDERVOLTAGE | 2,576 |  | - | - | Bulk | Active | - | - | - | - | - | - | - | - | 
|   | SE-325DNTNGR MON 120V NON-LATCH GF 0.1-5S | 4,632 |  |   Datasheet | SE-325 | Bulk | Active | Ground Fault, Overvoltage | 120VAC/DC | 0.5 ~ 4A | 0.1 ~ 2s | Chassis Mount | Screw Terminal | Manual Reset | -40°C ~ 60°C | 
|   | SE-325DSNNGR MON 120VAC/VDC NON-LATCH | 2,433 |  |   Datasheet | SE-325 | Bulk | Active | Ground Fault, Overvoltage | 120VAC/DC | 0.5 ~ 4A | 0.1 ~ 2s | Chassis Mount | Screw Terminal | Manual Reset | -40°C ~ 60°C | 
|   | SE-325DSTNGR MON 120VAC/VDC EXT RF GF 0.1 | 1,268 |  |   Datasheet | SE-325 | Bulk | Active | Ground Fault, Overvoltage | 120VAC/DC | 0.5 ~ 4A | 0.1 ~ 2s | Chassis Mount | Screw Terminal | Manual Reset | -40°C ~ 60°C | 
|   | PGR-6101-120MOTOR GROUND FAULT & INSUL RELAY | 2,041 |  |   Datasheet | POWR-GARD® | Bulk | Active | Ground Fault | 120VAC | - | 0.05 ~ 0.25s | Chassis Mount, DIN Rail | Screw Terminal | CT Loop Monitoring, Harmonic Filtering, Manual Reset, Test Button | -10°C ~ 60°C | 
|   | 1350X1350X=WILMAR CURRENT | 1,403 |  | - | - | Bulk | Active | - | - | - | - | - | - | - | - | 
|   | 1-1618060-71100DC-22SX=WILMAR CURRENT REL | 3,893 |  |   Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | 
|   | 1-1618062-01351-1X=WILMAR DIFFERENTIAL RE | 2,254 |  | - | - | Bulk | Active | - | - | - | - | - | - | - | - | 
|   | 56370TDRH99M GRD FLT RLY W/ 30MA DELAY | 2,592 |  |   Datasheet | MasterPacT ™ | Box | Obsolete | Ground Fault | 12 ~ 24VAC | 30mA | - | DIN Rail | Screw Terminal | - | - | 
|   | 56192EARTHLEAKAGE RELAY RH99M WITH AU | 1,199 |  |   Datasheet | VigiPacT | Box | Active | Ground Fault, Overcurrent | 110 ~ 130VAC | 30mA ~ 30A | 0 ~ 4.5s | DIN Rail | Screw Terminal | Test Button | -35°C ~ 70°C | 
|   | 56372TDGFR RH99M MANUAL TIME DELAY UL 1 | 1,221 |  | - | MasterPacT ™ | Box | Obsolete | Ground Fault | 110 ~ 130VAC | - | - | DIN Rail | Screw Terminal | - | - |