Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Grade | Qualification | Mounting Type | Supplier Device Package | Control Features | Approval Agency | Standard Number |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
TIM 2-4811DC DC CONVERTER 5V 2W Traco Power |
4,688 |
|
![]() Datasheet |
TIM 2 (2W) | 16-DIP Module, 7 Leads | Tube | Active | Isolated Module | 1 | 36V | 75V | 5V | - | - | - | 400mA | 2 W | 5 kV | Medical | Remote On/Off, OVP, SCP | -40°C ~ 95°C (With Derating) | 77% | - | - | Through Hole | - | - | - | - |
![]() |
TIM 2-0922DC DC CONVERTER +/-12V 2W Traco Power |
3,511 |
|
![]() Datasheet |
TIM 2 (2W) | 16-DIP Module, 7 Leads | Tube | Active | Isolated Module | 2 | 4.5V | 12V | 12V | -12V | - | - | 83mA, 83mA | 2 W | 5 kV | Medical | Remote On/Off, OVP, SCP | -40°C ~ 95°C (With Derating) | 81% | - | - | Through Hole | - | - | - | - |
![]() |
TIM 2-0923DC DC CONVERTER +/-15V 2W Traco Power |
3,391 |
|
![]() Datasheet |
TIM 2 (2W) | 16-DIP Module, 7 Leads | Tube | Active | Isolated Module | 2 | 4.5V | 12V | 15V | -15V | - | - | 67mA, 67mA | 2 W | 5 kV | Medical | Remote On/Off, OVP, SCP | -40°C ~ 95°C (With Derating) | 81% | - | - | Through Hole | - | - | - | - |
![]() |
TIM 2-1222DC DC CONVERTER +/-12V 2W Traco Power |
4,798 |
|
![]() Datasheet |
TIM 2 (2W) | 16-DIP Module, 7 Leads | Tube | Active | Isolated Module | 2 | 9V | 18V | 12V | -12V | - | - | 83mA, 83mA | 2 W | 5 kV | Medical | Remote On/Off, OVP, SCP | -40°C ~ 95°C (With Derating) | 81% | - | - | Through Hole | - | - | - | - |
![]() |
TEL 12-121312 WATT DC/DC CONVERTER, INDUSTR Traco Power |
4,820 |
|
![]() Datasheet |
TEL 12 (12W) | 16-DIP Module, 5 Leads | Tube | Active | Isolated Module | 1 | 9V | 18V | 15V | - | - | - | 800mA | 12 W | 1.8 kV | ITE (Commercial) | Baseplate | -40°C ~ 85°C | 88% | - | - | Through Hole | - | - | CB, cURus | - |
![]() |
TIM 2-4823DC DC CONVERTER +/-15V 2W Traco Power |
1,196 |
|
![]() Datasheet |
TIM 2 (2W) | 16-DIP Module, 7 Leads | Tube | Active | Isolated Module | 2 | 36V | 75V | 15V | -15V | - | - | 67mA, 67mA | 2 W | 5 kV | Medical | Remote On/Off, OVP, SCP | -40°C ~ 95°C (With Derating) | 81% | - | - | Through Hole | - | - | - | - |
![]() |
TIM 2-0912SMDC DC CONVERTER 12V 2W Traco Power |
1,563 |
|
![]() Datasheet |
TIM 2SM (2W) | 16-SMD Module, 7 Leads | Tube | Active | Isolated Module | 1 | 4.5V | 12V | 12V | - | - | - | 167mA | 2 W | 5 kV | Medical | Remote On/Off, OVP, SCP | -40°C ~ 95°C (With Derating) | 81% | - | - | Surface Mount | - | - | - | - |
![]() |
TIM 2-0913SMDC DC CONVERTER 15V 2W Traco Power |
4,648 |
|
![]() Datasheet |
TIM 2SM (2W) | 16-SMD Module, 7 Leads | Tube | Active | Isolated Module | 1 | 4.5V | 12V | 15V | - | - | - | 134mA | 2 W | 5 kV | Medical | Remote On/Off, OVP, SCP | -40°C ~ 95°C (With Derating) | 81% | - | - | Surface Mount | - | - | - | - |
![]() |
TIM 2-2422SMDC DC CONVERTER +/-12V 2W Traco Power |
3,515 |
|
![]() Datasheet |
TIM 2SM (2W) | 16-SMD Module, 7 Leads | Tube | Active | Isolated Module | 2 | 18V | 36V | 12V | -12V | - | - | 83mA, 83mA | 2 W | 5 kV | Medical | Remote On/Off, OVP, SCP | -40°C ~ 95°C (With Derating) | 81% | - | - | Surface Mount | - | - | - | - |
![]() |
TIM 2-2412SMDC DC CONVERTER 12V 2W Traco Power |
1,551 |
|
![]() Datasheet |
TIM 2SM (2W) | 16-SMD Module, 7 Leads | Tube | Active | Isolated Module | 1 | 18V | 36V | 12V | - | - | - | 167mA | 2 W | 5 kV | Medical | Remote On/Off, OVP, SCP | -40°C ~ 95°C (With Derating) | 80% | - | - | Surface Mount | - | - | - | - |