Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Grade | Qualification | Mounting Type | Supplier Device Package | Control Features | Approval Agency | Standard Number |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
TEN 15-2422WIDC DC CONVERTER +/-12V 15W Traco Power |
1,969 |
|
![]() Datasheet |
TEN 15WI (15W) | 6-DIP Module | Tube | Not For New Designs | Isolated Module | 2 | 9V | 36V | 12V | -12V | - | - | 625mA, 625mA | 15 W | 1.5 kV | ITE (Commercial) | Remote On/Off, SCP | -40°C ~ 85°C (With Derating) | 85% | - | - | Through Hole | - | - | - | - |
![]() |
TVN 5-0912WIDC DC CONVERTER 12V 5W Traco Power |
4,924 |
|
![]() Datasheet |
TVN 5WI (5W) | 24-DIP Module, 10 Leads | Tube | Active | Isolated Module | 1 | 4.5V | 12V | 12V | - | - | - | 416mA | 5 W | 1.6 kV | ITE (Commercial) | Remote On/Off, OCP, OVP, SCP | -40°C ~ 90°C (With Derating) | 87% | - | - | Through Hole | - | - | - | - |
![]() |
THM 20-2411DC DC CONVERTER 5V 20W Traco Power |
1,021 |
|
![]() Datasheet |
THM 20 (20W) | 5-DIP Module | Tube | Active | Isolated Module | 1 | 18V | 36V | 5V | - | - | - | 4A | 20 W | 5 kV | Medical | OCP, OTP, OVP, SCP | -40°C ~ 80°C (With Derating) | 90% | - | - | Through Hole | - | - | - | - |
![]() |
THM 20-1213DC DC CONVERTER 15V 20W Traco Power |
4,777 |
|
![]() Datasheet |
THM 20 (20W) | 5-DIP Module | Tube | Active | Isolated Module | 1 | 9V | 18V | 15V | - | - | - | 1.33A | 20 W | 5 kV | Medical | OCP, OTP, OVP, SCP | -40°C ~ 80°C (With Derating) | 88.5% | - | - | Through Hole | - | - | - | - |
![]() |
TEN 30-1212DC DC CONVERTER 12V 30W Traco Power |
3,987 |
|
![]() Datasheet |
TEN 30 (30W) | 6-DIP Module | Tube | Active | Isolated Module | 1 | 9V | 18V | 12V | - | - | - | 2.5A | 30 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | -40°C ~ 85°C (With Derating) | 89% | - | - | Through Hole | Module | - | - | - |
![]() |
TEN 30-4813DC DC CONVERTER 15V 30W Traco Power |
3,862 |
|
![]() Datasheet |
TEN 30 (30W) | 6-DIP Module | Tube | Active | Isolated Module | 1 | 36V | 75V | 15V | - | - | - | 2A | 30 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | -40°C ~ 85°C (With Derating) | 91% | - | - | Through Hole | Module | - | - | - |
![]() |
TVN 5-0923WIDC DC CONVERTER +/-15V 5W Traco Power |
2,083 |
|
![]() Datasheet |
TVN 5WI (5W) | 24-DIP Module, 12 Leads | Tube | Active | Isolated Module | 2 | 4.5V | 12V | 15V | -15V | - | - | 166mA, 166mA | 5 W | 1.6 kV | ITE (Commercial) | Remote On/Off, OCP, OVP, SCP | -40°C ~ 90°C (With Derating) | 86% | - | - | Through Hole | - | - | - | - |
![]() |
TRI 15-2411DC DC CONVERTER 5.1V 15W Traco Power |
3,875 |
|
![]() Datasheet |
TRI 15 (15W) | 5-DIP Module, 4 Leads | Tube | Active | Isolated Module | 1 | 18V | 36V | 5.1V | - | - | - | 3A | 15 W | 8 kV | ITE (Commercial) | - | -40°C ~ 85°C | 87% | - | - | Through Hole | - | - | CB, cURus | - |
![]() |
TEN 12-2410DC DC CONVERTER 3.3V 7.9W Traco Power |
2,589 |
|
![]() Datasheet |
TEN 12WI (12W) | 5-DIP Module, 4 Leads | Tube | Not For New Designs | Isolated Module | 1 | 9V | 36V | 3.3V | - | - | - | 2.4A | 7.9 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP, OVP, SCP | -40°C ~ 85°C (With Derating) | 78% | - | - | Through Hole | - | - | - | - |
![]() |
TEN 12-4810DC DC CONVERTER 3.3V 7.9W Traco Power |
1,365 |
|
![]() Datasheet |
TEN 12WI (12W) | 5-DIP Module, 4 Leads | Tube | Not For New Designs | Isolated Module | 1 | 18V | 75V | 3.3V | - | - | - | 2.4A | 7.9 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP, OVP, SCP | -40°C ~ 85°C (With Derating) | 78% | - | - | Through Hole | - | - | - | - |