| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
                 
                     
                 
                
                 | 
				
                    3-138-368LINE FILTER 80A CHASSIS MOUNT SCHURTER Inc.  |  
                4,993 | 
                
                     | 
                  
                  
                    
                       Datasheet  | 	
                
                FMBD EP | Box | Active | Three Phase (Wye) | Two Stage | - | - | 520 V | 760 V | 80 A | 50 ~ 60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block, Threaded Post (M6) | - | 
                 
                     
                 
                
                 | 
				
                    3-104-588LINE FILTER 230A CHASSIS MOUNT SCHURTER Inc.  |  
                3,372 | 
                
                     | 
                  
                  
                    
                       Datasheet  | 	
                
                FMAC NEO | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 230 A | 50 ~ 60Hz | General Purpose | cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Block, Threaded Post (M6) | - | 
                 
                     
                 
                
                 | 
				
                    FMBC-0960-3610LINE FILTER 480VAC 36A CHASS MNT SCHURTER Inc.  |  
                4,923 | 
                
                     | 
                  
                  
                    
                       Datasheet  | 	
                
                FMBC BOOK STYLE | Bulk | Obsolete | Three Phase (Delta) | Two Stage | - | 480V | - | - | 36 A | 50/60Hz | Inverters, Power Drive Systems | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | L1 - 1.5mH, L2 - 2mH | 
                 
                     
                 
                
                 | 
				
                    FMAC-091F-8010LINE FILTER 480VAC 80A CHASS MNT SCHURTER Inc.  |  
                1,949 | 
                
                     | 
                  
                  
                    
                       Datasheet  | 	
                
                FMAC ECO | Bulk | Active | Three Phase (Delta) | Single Stage | - | 480V | - | - | 80 A | 50 ~ 60Hz | Inverters, Power Drive Systems | ENEC | -25°C ~ 100°C | Chassis Mount | Terminal Block | 550µH | 
                 
                     
                 
                
                 | 
				
                    FMAC-0FBN-5000LINE FILTER 550VAC 50A CHASS MNT SCHURTER Inc.  |  
                2,817 | 
                
                     | 
                  
                  
                    
                       Datasheet  | 	
                
                FMAC-Out | Bulk | Active | Three Phase (Delta) | Single Stage | - | 550V | - | - | 50 A | 50 ~ 60Hz | General Purpose | ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | - | 
                 
                     
                 
                
                 | 
				
                    FMBC-A91R-4212LINE FILTER 480V/520VAC 42A CHAS SCHURTER Inc.  |  
                1,484 | 
                
                     | 
                  
                  
                    
                       Datasheet  | 	
                
                FMBC NEO | Bulk | Active | Three Phase (Delta) | Two Stage | - | 480V, 520V | - | - | 42 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | L1 - 1.3mH, L2 - 10µH | 
                 
                     
                 
                
                 | 
				
                    3-138-327LINE FILTER 110A CHASSIS MOUNT SCHURTER Inc.  |  
                4,635 | 
                
                     | 
                  
                  
                    
                       Datasheet  | 	
                
                FMBC EP | Box | Active | Three Phase (Delta) | Two Stage | - | - | 520 V | 760 V | 110 A | 50 ~ 60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block, Threaded Post (M6) | - | 
                 
                     
                 
                
                 | 
				
                    FMBC-0996-6600LINE FILTER 480VAC 66A CHASS MNT SCHURTER Inc.  |  
                3,540 | 
                
                     | 
                  
                  
                    
                       Datasheet  | 	
                
                FMBC ECO | Box | Active | Three Phase (Delta) | Two Stage | - | 480V | - | - | 66 A | 50/60Hz | Inverters, Power Drive Systems | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 450µH | 
                 
                     
                 
                
                 | 
				
                    3-138-355LINE FILTER 110A CHASSIS MOUNT SCHURTER Inc.  |  
                3,171 | 
                
                     | 
                  
                  
                    
                       Datasheet  | 	
                
                FMBD EP | Box | Active | Three Phase (Wye) | Two Stage | - | - | 520 V | 760 V | 110 A | 50 ~ 60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block, Threaded Post (M6) | - | 
                 
                     
                 
                
                 | 
				
                    3-138-341LINE FILTER 110A CHASSIS MOUNT SCHURTER Inc.  |  
                1,265 | 
                
                     | 
                  
                  
                    
                       Datasheet  | 	
                
                FMBC EP | Box | Active | Three Phase (Delta) | Two Stage | - | - | 520 V | 760 V | 110 A | 50 ~ 60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block, Threaded Post (M6) | - |