| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Sensor Type | Humidity Range | Output Type | Output | Accuracy | Response Time | Sensitivity | Voltage - Supply | Mounting Type | Operating Temperature | Grade | Qualification | Supplier Device Package | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
                 
                     
                 
                
                 | 
				
                    A/RH3-CP-RSO-A04-C5Relative Humidity, RH Outputs: 0 Automation Components, Inc.  |  
                2,583 | 
                
                     | 
                  
                  
                     -  | 	
                
                - | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - | 
                 
                     
                 
                
                 | 
				
                    A/RH3-50K-SP-010Relative Humidity, RH Outputs: 0 Automation Components, Inc.  |  
                1,145 | 
                
                     | 
                  
                  
                    
                       Datasheet  | 	
                
                - | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Voltage | 0V ~ 10V | ±3% RH | 20 s | - | 18 ~ 28VAC, 18 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - | 
                 
                     
                 
                
                 | 
				
                    A/RH3-50K-ORelative Humidity, RH Outputs: 0 Automation Components, Inc.  |  
                4,977 | 
                
                     | 
                  
                  
                    
                       Datasheet  | 	
                
                - | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module | 
                 
                     
                 
                
                 | 
				
                    A/RH3-CP-R2SO-A08-C5Relative Humidity, RH Outputs: 0 Automation Components, Inc.  |  
                4,450 | 
                
                     | 
                  
                  
                    
                       Datasheet  | 	
                
                A/RHx-CP | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | Module | 
                 
                     
                 
                
                 | 
				
                    A/RH3-CSI-RSO-A29-C5Relative Humidity, RH Outputs: 0 Automation Components, Inc.  |  
                2,321 | 
                
                     | 
                  
                  
                    
                       Datasheet  | 	
                
                A/RHx-CSI | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | Module | 
                 
                     
                 
                
                 | 
				
                    A/RH3-AN-R2SO-A03-G5Relative Humidity, RH Outputs: 0 Automation Components, Inc.  |  
                1,255 | 
                
                     | 
                  
                  
                    
                       Datasheet  | 	
                
                A/RHx-AN | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | Module | 
                 
                     
                 
                
                 | 
				
                    A/RH3-CP-R2SO-A03-G5Relative Humidity, RH Outputs: 0 Automation Components, Inc.  |  
                2,312 | 
                
                     | 
                  
                  
                    
                       Datasheet  | 	
                
                A/RHx-CP | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | Module | 
                 
                     
                 
                
                 | 
				
                    A/RH3-3K-O-BBRelative Humidity, RH Outputs: 0 Automation Components, Inc.  |  
                2,794 | 
                
                     | 
                  
                  
                    
                       Datasheet  | 	
                
                - | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module | 
                 
                     
                 
                
                 | 
				
                    A/RH3-CP-RSO-A03-C5Relative Humidity, RH Outputs: 0 Automation Components, Inc.  |  
                2,037 | 
                
                     | 
                  
                  
                    
                       Datasheet  | 	
                
                A/RHx-CP | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | Module | 
                 
                     
                 
                
                 | 
				
                    A/RH3-10K-E1-SP-010Relative Humidity, RH Outputs: 0 Automation Components, Inc.  |  
                4,803 | 
                
                     | 
                  
                  
                    
                       Datasheet  | 	
                
                - | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Voltage | 0V ~ 10V | ±3% RH | 20 s | - | 18 ~ 28VAC, 18 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |