Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Voltage - Rated | Size / Dimension | Width | Air Flow | Static Pressure | Bearing Type | Fan Type | Features | Noise | Power (Watts) | RPM | Termination | Ingress Protection | Operating Temperature | Approval Agency | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
GF60252B3-1000U-FEP24VDC FAN 60X25MM TACH IP68 Sunon Fans |
1,011 |
|
![]() Datasheet |
GF | Box | Active | 24VDC | Square - 60mm L x 60mm H | 25.40mm | 26.9 CFM (0.753m³/min) | 0.420 in H2O (104.6 Pa) | Ball | Tubeaxial | Locked Rotor Sensor | 38.0dB(A) | 2.76 W | 6450 RPM | 3 Wire Leads | IP68 - Dust Tight, Waterproof | - | CCC, CE, cURus, TUV, UKCA | - |
![]() |
GF60252BX-1000U-FDP24VDC FAN 60X25MM TACH GR487 Sunon Fans |
3,944 |
|
![]() Datasheet |
GF | Box | Active | 24VDC | Square - 60mm L x 60mm H | 25.40mm | 54.6 CFM (1.53m³/min) | 1.440 in H2O (358.7 Pa) | Ball | Tubeaxial | Locked Rotor Sensor | 55.4dB(A) | 13.08 W | 12900 RPM | 3 Wire Leads | - | - | CCC, CE, cURus, TUV, UKCA | - |
![]() |
GF60252BX-1000U-SEP24VDC FAN 60X25MM TACH/PWM IP68 Sunon Fans |
4,106 |
|
![]() Datasheet |
GF | Box | Active | 24VDC | Square - 60mm L x 60mm H | 25.40mm | 54.6 CFM (1.53m³/min) | 1.440 in H2O (358.7 Pa) | Ball | Tubeaxial | PWM Control | 55.4dB(A) | 13.08 W | 12900 RPM | 3 Wire Leads | IP68 - Dust Tight, Waterproof | - | CCC, CE, cURus, TUV, UKCA | - |
![]() |
GF60252B1-1000U-SDP24VDC FAN 60X25MM TACH/PWM GR487 Sunon Fans |
1,434 |
|
![]() Datasheet |
GF | Box | Active | 24VDC | Square - 60mm L x 60mm H | 25.40mm | 48.1 CFM (1.35m³/min) | 1.210 in H2O (301.4 Pa) | Ball | Tubeaxial | PWM Control | 53.2dB(A) | 9.72 W | 11500 RPM | 3 Wire Leads | - | - | CCC, CE, cURus, TUV, UKCA | - |
![]() |
GF60252B3-1000U-SDP24VDC FAN 60X25MM TACH/PWM GR487 Sunon Fans |
1,855 |
|
![]() Datasheet |
GF | Box | Active | 24VDC | Square - 60mm L x 60mm H | 25.40mm | 26.9 CFM (0.753m³/min) | 0.420 in H2O (104.6 Pa) | Ball | Tubeaxial | PWM Control | 38.0dB(A) | 2.76 W | 6450 RPM | 3 Wire Leads | - | - | CCC, CE, cURus, TUV, UKCA | - |
![]() |
GF60252B2-1000U-SEP24VDC FAN 60X25MM TACH/PWM IP68 Sunon Fans |
3,970 |
|
![]() Datasheet |
GF | Box | Active | 24VDC | Square - 60mm L x 60mm H | 25.40mm | 36.3 CFM (1.02m³/min) | 0.790 in H2O (196.8 Pa) | Ball | Tubeaxial | PWM Control | 47.2dB(A) | 5 W | 9000 RPM | 3 Wire Leads | IP68 - Dust Tight, Waterproof | - | CCC, CE, cURus, TUV, UKCA | - |
![]() |
GF60252B3-1000U-SEP24VDC FAN 60X25MM TACH/PWM IP68 Sunon Fans |
1,288 |
|
![]() Datasheet |
GF | Box | Active | 24VDC | Square - 60mm L x 60mm H | 25.40mm | 26.9 CFM (0.753m³/min) | 0.420 in H2O (104.6 Pa) | Ball | Tubeaxial | PWM Control | 38.0dB(A) | 2.76 W | 6450 RPM | 3 Wire Leads | IP68 - Dust Tight, Waterproof | - | CCC, CE, cURus, TUV, UKCA | - |
![]() |
PF80381BX-000U-A99FAN AXIAL 80X38MM 12VDC WIRE Sunon Fans |
4,587 |
|
![]() Datasheet |
PF | Box | Obsolete | 12VDC | Square - 80mm L x 80mm H | 38.00mm | 141.9 CFM (3.97m³/min) | 3.200 in H2O (797.1 Pa) | Ball | Tubeaxial | Auto Restart | 72.1dB(A) | 48 W | 14000 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CE, CUR, TUV, UL | 0.43 lb (195.04 g) |
![]() |
GF60252B3-1000U-QDP24VDC 60X25MM ALARM/PWM GR487 Sunon Fans |
3,808 |
|
![]() Datasheet |
GF | Box | Active | 24VDC | Square - 60mm L x 60mm H | 25.40mm | 26.9 CFM (0.753m³/min) | 0.420 in H2O (104.6 Pa) | Ball | Tubeaxial | PWM Control | 38.0dB(A) | 2.76 W | 6450 RPM | 3 Wire Leads | - | - | CCC, CE, cURus, TUV, UKCA | - |
![]() |
GF60252BX-1000U-QEP24VDC FAN 60X25MM ALARM/PWM IP68 Sunon Fans |
2,891 |
|
![]() Datasheet |
GF | Box | Active | 24VDC | Square - 60mm L x 60mm H | 25.40mm | 54.6 CFM (1.53m³/min) | 1.440 in H2O (358.7 Pa) | Ball | Tubeaxial | PWM Control | 55.4dB(A) | 13.08 W | 12900 RPM | 3 Wire Leads | IP68 - Dust Tight, Waterproof | - | CCC, CE, cURus, TUV, UKCA | - |