| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Operating Temperature | Features | Mounting Type | Size / Dimension |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
NMP1K2-EEEE#K-00AC/DC CONVERTER 4X12V 48V 1200W |
2,393 |
|
Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 12V | 12V | 12V | 12V | 48V | - | 20 A | 20 A | 20 A | 20 A | 5 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-EEEEC#-00AC/DC CONVERTER 4X12V 5V 1140W |
3,824 |
|
Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 12V | 12V | 12V | 12V | 5V | - | 20 A | 20 A | 20 A | 20 A | 36 A | - | 1140W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-EEEEE#-00AC/DC CONVERTER 5X12V 1200W |
2,945 |
|
Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 12V | 12V | 12V | 12V | 12V | - | 20 A | 20 A | 20 A | 20 A | 20 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-EEEEH#-00AC/DC CONVERTER 4X12V 24V 1200W |
2,252 |
|
Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 12V | 12V | 12V | 12V | 24V | - | 20 A | 20 A | 20 A | 20 A | 10 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-EEEEK#-00AC/DC CONVERTER 4X12V 48V 1200W |
1,424 |
|
Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 12V | 12V | 12V | 12V | 48V | - | 20 A | 20 A | 20 A | 20 A | 5 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-EEEH#C-00AC/DC CNVT 3X12V 24V 5V 1140W |
3,364 |
|
Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 12V | 12V | 12V | 24V | 5V | - | 20 A | 20 A | 20 A | 10 A | 36 A | - | 1140W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-EEEH#E-00AC/DC CNVT 3X12V 24V 12V 1200W |
3,552 |
|
Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 12V | 12V | 12V | 24V | 12V | - | 20 A | 20 A | 20 A | 10 A | 20 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-EEEH#H-00AC/DC CNVT 3X12V 2X24V 1200W |
2,666 |
|
Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 12V | 12V | 12V | 24V | 24V | - | 20 A | 20 A | 20 A | 10 A | 10 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-EEEH#K-00AC/DC CNVT 3X12V 24V 48V 1200W |
1,673 |
|
Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 12V | 12V | 12V | 24V | 48V | - | 20 A | 20 A | 20 A | 10 A | 5 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-EEEHC#-00AC/DC CNVT 3X12V 24V 5V 1140W |
3,370 |
|
Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 12V | 12V | 12V | 24V | 5V | - | 20 A | 20 A | 20 A | 10 A | 36 A | - | 1140W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-EEEHE#-00AC/DC CNVT 3X12V 24V 12V 1200W |
2,829 |
|
Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 12V | 12V | 12V | 24V | 12V | - | 20 A | 20 A | 20 A | 10 A | 20 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-EEEHH#-00AC/DC CNVT 3X12V 2X24V 1200W |
3,035 |
|
Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 12V | 12V | 12V | 24V | 24V | - | 20 A | 20 A | 20 A | 10 A | 10 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-EEEHK#-00AC/DC CNVT 3X12V 24V 48V 1200W |
1,690 |
|
Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 12V | 12V | 12V | 24V | 48V | - | 20 A | 20 A | 20 A | 10 A | 5 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-EEEK#C-00AC/DC CNVT 3X12V 48V 5V 1140W |
2,347 |
|
Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 12V | 12V | 12V | 48V | 5V | - | 20 A | 20 A | 20 A | 5 A | 36 A | - | 1140W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-EEEK#E-00AC/DC CNVT 3X12V 48V 12V 1200W |
1,666 |
|
Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 12V | 12V | 12V | 48V | 12V | - | 20 A | 20 A | 20 A | 5 A | 20 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-EEEK#H-00AC/DC CNVT 3X12V 48V 24V 1200W |
4,288 |
|
Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 12V | 12V | 12V | 48V | 24V | - | 20 A | 20 A | 20 A | 5 A | 10 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-EEEK#K-00AC/DC CNVT 3X12V 2X48V 1200W |
3,441 |
|
Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 12V | 12V | 12V | 48V | 48V | - | 20 A | 20 A | 20 A | 5 A | 5 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-EEEKC#-00AC/DC CNVT 3X12V 48V 5V 1140W |
3,343 |
|
Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 12V | 12V | 12V | 48V | 5V | - | 20 A | 20 A | 20 A | 5 A | 36 A | - | 1140W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-EEEKE#-00AC/DC CNVT 3X12V 48V 12V 1200W |
1,393 |
|
Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 12V | 12V | 12V | 48V | 12V | - | 20 A | 20 A | 20 A | 5 A | 20 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
|
NMP1K2-EEEKH#-00AC/DC CNVT 3X12V 48V 24V 1200W |
3,934 |
|
Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 12V | 12V | 12V | 48V | 24V | - | 20 A | 20 A | 20 A | 5 A | 10 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |